Wine cooler compressor change
I replace a compressor on a glass door wine cooler
Allied Refrigeration 440-823-5720
Cleveland, Ohio
Переглядів: 39 418

Відео

Old MP 39 heat reclaim system convert to R 134a and POE oil
Переглядів 16 тис.8 років тому
The old heat reclaim valve was stuck open heating the store fighting the air conditioning. Allied Refrigeration 440-823-5720 Cleveland, ohio
Rheem two stage rooftop AC compressor change
Переглядів 36 тис.8 років тому
We replace a copeland schroll compressor on a Rheem two stage roof top AC unit. The camera didn't get all of the ending. Allied Refrigeration 440-823-5720 Cleveland, Ohio
Single door Continental Freezer
Переглядів 16 тис.8 років тому
service work done on a used single door freezer
schroll compressor replaces an old recriprocating compressor
Переглядів 45 тис.8 років тому
I replace the old recripocating compressor to glass door cooler with a schroll compressor Allied Refrigeration 440-823-5720
Fun with electronics
Переглядів 20 тис.8 років тому
This is how I have fun, electronics can be a source of fustration so I enjoyed pulling this electronic device out and installed a good old standard Ranco dual pressure control and got the freezer running.
Replace a 5 ton AC unit at a Puerto Rican market
Переглядів 26 тис.8 років тому
I replace a 5 ton air conditioning condensing unit Allied Refrigeration 440-823-5720 Cleveland, Ohio
Low evaporator saturation point
Переглядів 33 тис.8 років тому
This beer cooler has the wrong evaporator in it. Allied Refrigeration 440-823-5720 Cleveland, Ohio
Soda coolers with dirty condensers
Переглядів 7 тис.8 років тому
dirty condensers and 2 True glass door coolers with R290
One year old compressor failed, time to troubleshoot
Переглядів 70 тис.8 років тому
I have to figure out why this compressor failed Allied Refrigeration 440-823-5720 Cleveland, Ohio
Refrigeration system low on refrigerant
Переглядів 38 тис.8 років тому
I charge a rooftop condensing unit
Tin knocking
Переглядів 6 тис.8 років тому
I fabricate a sheet metal return elbow Allied Refrigeration 440-823-5720 Cleveland, Ohio
Expansion valve replace and adjust
Переглядів 143 тис.8 років тому
The old expansion valve was hunting badly, I replaced it and adjusted it. Allied Refrigeration 440-823-5720 Cleveland, Ohio
True Two door freezer not cold
Переглядів 81 тис.8 років тому
repair a freezer Allied Refrigeration 440-823-5720 Cleveland, Ohio
Trouble shoot and trace the control circuit wiring on a walk in cooler
Переглядів 37 тис.8 років тому
I trace out the control circuit Allied Refrigeration 440-823-5720 Cleveland , Ohio
Sheet metal weatherproof condensing unit cover part 2
Переглядів 5 тис.8 років тому
Sheet metal weatherproof condensing unit cover part 2
Sheet metal weatherproof condensing unit cover part 1
Переглядів 5 тис.8 років тому
Sheet metal weatherproof condensing unit cover part 1
Trane AC unit compressor change part 1
Переглядів 37 тис.8 років тому
Trane AC unit compressor change part 1
Techumseh Compressor change on a soda cooler
Переглядів 21 тис.8 років тому
Techumseh Compressor change on a soda cooler
Magic Bullet ? Honeywell's N40 (R448A)
Переглядів 10 тис.8 років тому
Magic Bullet ? Honeywell's N40 (R448A)
JJ's Greenhouse part2
Переглядів 8 тис.8 років тому
JJ's Greenhouse part2
J Js Greenhouse low air high humidity evap install part 1
Переглядів 12 тис.8 років тому
J Js Greenhouse low air high humidity evap install part 1
Winter wonderland on a roof dual pressure control change
Переглядів 18 тис.8 років тому
Winter wonderland on a roof dual pressure control change
Defrost time clock replacement and wiring
Переглядів 32 тис.8 років тому
Defrost time clock replacement and wiring
Temperature control change out on a Chinese walk in cooler
Переглядів 16 тис.8 років тому
Temperature control change out on a Chinese walk in cooler
1/2 HP condenser fan motor adaption on a refrigeration condensing unit 1
Переглядів 5 тис.8 років тому
1/2 HP condenser fan motor adaption on a refrigeration condensing unit 1
Old 1994 HP81 Manitowoc Ice Machine problem solving part 1
Переглядів 23 тис.8 років тому
Old 1994 HP81 Manitowoc Ice Machine problem solving part 1
Old 1994 HP81 Manitowoc Ice Machine problem solving part2
Переглядів 19 тис.8 років тому
Old 1994 HP81 Manitowoc Ice Machine problem solving part2
Leak refrigerant spurting out a pin hole
Переглядів 11 тис.8 років тому
Leak refrigerant spurting out a pin hole
Compressor change on walk in cooler
Переглядів 62 тис.8 років тому
Compressor change on walk in cooler

КОМЕНТАРІ

  • @thanosgeorgopoulos5885
    @thanosgeorgopoulos5885 3 дні тому

    what could i do to make long harvest cycle besides hammer and screwdriver ??

  • @TonyRodriguez-ok2ix
    @TonyRodriguez-ok2ix 6 днів тому

    mineral oil would stick to chlorine poe oil floats threw the system.sum times the oil can float and get stuck on top of the refrigerant in the reciever according to emerson. the cure was adding a bit of mineral oil so it could help push the poe oil.

  • @TonyRodriguez-ok2ix
    @TonyRodriguez-ok2ix 6 днів тому

    digital controls are a weak link in the electrical system they can get damged in a short situation

  • @alfonsotoscano5096
    @alfonsotoscano5096 22 дні тому

    The best teacher that I could ever find. Thanks for sharing your knowledge.

  • @glenjones4404
    @glenjones4404 29 днів тому

    The condensing unit needs turning round 💯 as the hot air is not going to escape any where Plus its hard to work on as its been fitted backwards 🤠 Fitted by cow bows 🤯😂😂😂

  • @user-ko2cz5jr2c
    @user-ko2cz5jr2c Місяць тому

    Why not have the fans draw the air through the coil

  • @abaidrehman4883
    @abaidrehman4883 Місяць тому

    So wonderful lecture thoroughly explained thank you so much.

  • @ilovenythismuchilovenewyor5801
    @ilovenythismuchilovenewyor5801 Місяць тому

    yea but aren't u adding air into the lines doing it like that

  • @user-bq9ur8se9b
    @user-bq9ur8se9b Місяць тому

    You should clean the fan before you put it back together! 😮 or your helper!

  • @LadariusCapersOfficial
    @LadariusCapersOfficial 2 місяці тому

    The coils can use a little love to 😊

  • @glenjones4404
    @glenjones4404 2 місяці тому

    The condensing unit needs utting out side with an housing as it will always struggle up there with the heat building up

  • @glenjones4404
    @glenjones4404 2 місяці тому

    Blocked condenser as its in a dusty environment so the condenser needs blowing out

  • @glenjones4404
    @glenjones4404 2 місяці тому

    When you adjustment on txv you should ut the top back on as your letting alot of hot air enter which will drive it up the wall plus you could add a sight glass in the future which would make easier to diagnose next time

  • @glenjones4404
    @glenjones4404 2 місяці тому

    Starved coil

  • @glenjones4404
    @glenjones4404 2 місяці тому

    The compressor sounds like it screaming loke its under pressure very loud tone

  • @pedrojardim325
    @pedrojardim325 3 місяці тому

    Hi. There Good stuff jim😊

  • @CRESEDA
    @CRESEDA 3 місяці тому

    Thank You Sir, Excellent Video!

  • @user-de8fi2ih3s
    @user-de8fi2ih3s 3 місяці тому

    Your the man!!!!

  • @williamworth2746
    @williamworth2746 3 місяці тому

    Teaching your apprentice right i had wrenches thrown at me. There are allot of alcoholics in HVAC-R

  • @memimonimo
    @memimonimo 3 місяці тому

    I need to know if this old compressor using ammonia or freon 12 or other things.

  • @brandoncorrea511
    @brandoncorrea511 4 місяці тому

    What fan motor he used to replace?

  • @dhaslam003
    @dhaslam003 4 місяці тому

    The system is low on refrigerant or has a plugged drier. Sight glass not supposed to flash in low ambient. It’s flashing because refrigerant is stacking in condenser to keep up head pressure and there isn’t enough liquid in receiver. Clear glass and add an extra #. That’s what I would do.

  • @sparkyedu
    @sparkyedu 4 місяці тому

    I thought semi compressors are better why would you down grade?

  • @951cast
    @951cast 4 місяці тому

    How are you getting the TD?

  • @abazism
    @abazism 5 місяців тому

    Can you please tell me the what the the super heat should be for freezer and cooler ? 8-12 for freezer and 15 for cooler ?

  • @bigdaddy4975
    @bigdaddy4975 5 місяців тому

    where is this guy now?

  • @robertbeckler5058
    @robertbeckler5058 5 місяців тому

    Don't yah love the dull zip screws.

  • @tbone6354
    @tbone6354 6 місяців тому

    A very helpful tip to extend the life of the compressor is to add 50ml of water to the compressor before regassing. This will cool the compressor

  • @uptownphotography
    @uptownphotography 6 місяців тому

    I have a GE condenser motor that keeps stopping or spinning very slowly on a Kenmore older frig. Great idea as i was going to remove the metal cap to oil the bearing but I like your idea if i can find my awl. I am having trouble locating a replacement motor if you have any ideas where to buy that would be great. My motor is basically all metal design, like yours, rather then these cheap plastic replacements... Phil Jersey Shore Area

  • @bigdaddy4975
    @bigdaddy4975 6 місяців тому

    Can anyone tell what happened to Jim all I see are 10 year old videos?

  • @douglasdc6516
    @douglasdc6516 6 місяців тому

    I love these old Refrigeration mechanical rooms from these old mom and pop stores I’ve managed to rescue over 12 of these belt drive condensers over the years , I love them !

  • @reynaldolacayo6594
    @reynaldolacayo6594 6 місяців тому

    señor !! what happen with you ?? are you got out of business !! i used to love you videos

  • @billkentli
    @billkentli 7 місяців тому

    Super Work. Hallo from Germany...

  • @winkhvac62
    @winkhvac62 7 місяців тому

    Thank you Jim

  • @richiegarcia-lopez4268
    @richiegarcia-lopez4268 7 місяців тому

    The purpose of superheat is to make sure you have a flooded evaporator but aren’t flooding back to the compressor which would cause premature failure. Refrigerant keeping the compressor from overheating is simply a byproduct of the refrigeration cycle.

  • @douro20
    @douro20 8 місяців тому

    I wonder if Frigidaire built any belt-drive walk-in cooler refrigeration units? The A-6 swashplate compressor would had worked well for that.

  • @Justin-vr5zn
    @Justin-vr5zn 8 місяців тому

    whhhaaattt? how are you able to work without a van full of packout? did people really have to work like this back in ancient times? looks like something out of the flintstones.

  • @garypoplin4599
    @garypoplin4599 8 місяців тому

    19:57 - Tightening a seized nut before loosening it makes it easer to remove. If you hadn’t said anything I would have thought you did it on purpose!

  • @garypoplin4599
    @garypoplin4599 8 місяців тому

    10:26 - Just for everyone’s benefit, the dimple maker on your crimps are for bare connectors only. Insulated connectors are crimped with the oval part of your crimps (just sayin’). Thanks for sharing your work techniques.

  • @abazism
    @abazism 9 місяців тому

    Should I first clear the sight glass then adjust the txv ?

  • @comeonwindows7
    @comeonwindows7 10 місяців тому

    hi, is this compressor an inverter technology?

  • @user-uu3qj2ox8v
    @user-uu3qj2ox8v 10 місяців тому

    شكرا

  • @arcticzone9223
    @arcticzone9223 Рік тому

    Must be the reason my coil keep icing up

  • @ArisBuliteanu
    @ArisBuliteanu Рік тому

    12:40

  • @ArisBuliteanu
    @ArisBuliteanu Рік тому

    14:34

  • @ArisBuliteanu
    @ArisBuliteanu Рік тому

    14:31

  • @ArisBuliteanu
    @ArisBuliteanu Рік тому

    24:05

  • @ArisBuliteanu
    @ArisBuliteanu Рік тому

    24:06

  • @ArisBuliteanu
    @ArisBuliteanu Рік тому

    24:07

  • @ArisBuliteanu
    @ArisBuliteanu Рік тому

    24:08